The 6712FR is a composite or sequential refrigerated sampler and is designed to withstand the harshest indoor or outdoor environments. The unequalled 'FR' refrigerator cabinet is corrosion-proof and moulded from polyester resin fiberglass, supported by a stainless steel frame. Samples are preserved at the EPA-recommended 4 °C (39 °F). The sampler has thick, foamed-in-place insulation, and to ensure samples won't freeze there's an automatically controlled, built-in heater.
Programming is simple and fast, with online help just a key stroke away if needed. To achieve the routine that is most suitable for your application, the advanced 6712 Controller allows the user to select different programming modes. Standard Programming Mode walks the user through the sampling sequence step-by-step, allowing all parameters specific to your application to be selected.. In Extended Programming Mode more complex programs can be entered, including smart sampling event notification, triggered on up to 16 inputs.
Manufactured by: Teledyne ISCO
Model: 6712FR ISCO Refrigerated Sampler
Wastewater effluent
Stormwater monitoring
CSO monitoring
Permit compliance
Pretreatment compliance
Sampler | |
Size (H x W x D) | 49.3 x 26 x 26 inches (125 cm x 66 x 66 cm) |
Weight (Dry) | 160 lbs (73 kg) |
Refrigerator Body | Fiberglass reinforced plastic with UV-resistant gel coat |
Power Required | 120 VAC, 60 Hz; OR 240 VAC, 50 Hz (specify) |
Pump | |
Intake Purge | Adjustable air purge before and after each sample. |
Tubing Life Indicator | Provides a warning to change pump tubing. |
Intake Suction Tubing | Vinyl or PTFE/FEP 3/8 inch (1 cm) ID; 3 to 99 feet (1 to 30 m) Length |
Pump Tubing Life | Typically 1,000,000 pump counts |
Maximum Lift | 28 feet (8.5 m) |
Repeatability | Typical ±5 ml or ±5% of the average volume in a set |
Typical Line Velocity @ Head Height | 3.0 ft./s @ 3 ft; 2.9 ft./s @ 10 ft; 2.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m) |
Liquid Presence Detector | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller | |
Weight | 13 lbs. (5.9 kg) |
Size (HxWxD) | 10.3 x 12.5 x 10 inches (26 x 31.7 x 25.4 cm) |
Operational Temperature | 32° to 120°F (0° to 49°C) |
Controller (continued) | |
Enclosure Rating | NEMA 4X, 6 IP67 |
Program Memory | Non-volatile ROM |
Flow Meter Signal Input | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure. |
Number of Composite Samples | I Programmable from 1 to 999 samples. |
Clock Accuracy | 1 minute per month, typical, for real time clock |
Software | |
Sample Frequency | 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
Sampling Modes | Uniform time, non-uniform time, flow, event. (Flow mode is controlled by external flow meter pulses.) |
Programmable Sample Volumes | 10 to 9,990 ml in 1 ml increments |
Sample Retries | If no sample is detected, up to 3 attempts; user selectable |
Rinse Cycles | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program Storage | 5 sampling programs |
Sampling Stop/Resume | Up to 24 real time/date sample stop/resume commands |
Controller Diagnostics | Tests for RAM, ROM, pump display, and distributor |