The 3710 Automatic Sampler is simple to operate and has high volume capacity for single - bottle sampling. Composite samples can be collected either at flow or time based intervals.
Auotmatic samples can be collected in either a 2.5 gallon glass or polyethylene bottle, or a 4 gallon polyethylene bottle. Up to 24 sampling stop and resume times can be preset for unattended, automatic sampling.
Set up and programming of the automatic sampler is easily done. All the user has to do is choose the options needed from the selections displayed on the two-line, backlit LCD.
The ISCO 3710 automatic sampler has a thermal resistance of R-11 which allows maximum effectiveness for cooling samples. The base of the sampler is insulated by one inch thick foam, keeping the unit more rigid and less affected by ambient temperatures.
Standard Features
Applications
Options and Accessories
Manufactured by: Teledyne ISCO
Model: ISCO 3710 Portable Sampler
Watewater effluent
CSO monitoring
Permit compliance
Pretreatment compliance
Sampler | |
Size (Diam x Ht) | 19 x 28 inches (49 x 73 cm) |
Weight (dry) | Dry, less battery - 32 lbs (14.5 kg) |
Material | Fiberglass-reinforced plastic with UV-resistant gel coat |
Power required | 12 VDC (Supplied by battery or AC power converter.) |
Pump | |
Intake purge | Adjustable air purge before and after each sample. |
Tubing life indicator | Provides a warning to change pump tubing. |
Pump tubing life | Recommended 500,000 pump counts |
Intake suction tubing | Vinyl or Teflon®; 3/8 inch (1 cm) or 1/4 inch (0.6cm) ID; 3 to 99 feet (1 to 30 m) Length |
Maximum lift | 26 ft. (7.9 m) |
Repeatability | ±10 ml typical |
Typical line velocity @ Head height | 2.5 ft./s @ 3 ft; 2.5 ft./s @ 10 ft; 1.9 ft./s @ 15 ft. (0.76 m/s @ 0.9 m; 0.76 m/s @ 3.1 m; 0.58 m/s @ 4.6 m) |
Liquid presence detector | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller | |
Weight | 11 lbs (5 kg) |
Size (HxWxD) | 10 x 12.5 x 10 inches (25 x 32 x 25 cm) |
Operational temperature | 32° to 120°F (0° to 49°C) |
Enclosure rating | NEMA 4X, 6 IP67 |
Program memory | Non-volatile ROM |
Flow meter signal input | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure. |
Number of Samples | Up to 200 composite samples. (Fail-safe float shutoff.) |
Interface port | 8 pin connector; data output at 2400 baud in ASCII. RS-232 format with handshake. |
Clock accuracy | 1 minute per month, typical, for real time clock |
Software | |
Sample frequency | 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
Sample pacing | Uniform time, non-uniform time, flow. Flow pacing is controlled by external flowmeter pulses. |
Sample volumes | Programmable from 10 to 9,990 ml in 1 ml increments |
Sample retries | If no sample is detected, up to 3 attempts; user selectable |
Rinse cycles | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program storage | 3 sampling programs |
Sampling stop/resume | Up to 24 real time/date sample stop/resume commands. |
Controller diagnostics | Tests for RAM, ROM, pump display, and distributor |