Size (HxWxD) |
8.88 x 12.22 x 8.22 in. (with mounting bracket) |
Materials of Construction |
PPO Polyphenylene Oxide |
Enclosure (self-certified) |
NEMA 4X/IP66 |
Power Required |
100 to 240 VAC 50/60 Hz |
Cable Entry |
Standard: 3/4" NPT conduit
Optional: 3/4" NPT cord grips |
Flow Measurement Technologies |
Ultrasonic (TIENet 310)
Bubbler (TIENet 330) |
Inputs |
Two SDI-12
Two MODBUS ASCII/RTU
pH Measurement (TIENet 301) |
Setup |
Front Panel Keypad
Flowlink Software - with serial USB, remote cellular, or Ethernet |
Flow Conversions |
Weir, Flume, British Flume, Metering Insert, Manning
Formula, Equation, Level to Flow Data Points |
Data Storage |
Non-volatile flash; retains stored data during program updates. Capacity: 512 KB
Interval: 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours
Capacity: 180 days with 5 parameters logged at 1 minute intervals, reports once per day |
Data Retrieval |
USB drive
Flowlink Software - with serial USB, remote cellular, or Ethernet |
Outputs |
MODBUS ASCII/RTU
Analog (TIENet 308)
SMS Alarm |
Sampler Interface |
TIENet 306 |
Communication Options |
CDMA or GSM cellular, Ethernet |
Temperature Range: Operating and Storage |
-20 to 60°C (-4 to 140°F) |
TIENet™ 301 pH/Temperature Device |
Weight (w/o probe) |
w/ 10m cable: 3.5 lb
w/ 23m cable: 7.5 lb |
Ambient Operating Temperature |
-20 to 50°C (-4 to 122°F) |
pH Measurement Range |
0 - 14 pH units |
Temperature Compensation |
Performed by the 301 device |
pH Accuracy |
±0.1 pH units (new probe, freshly calibrated w/in range) |
Probe Dimensions |
1.12" Ø X 6" long, 3/4 NPT; Cable 25ft |
Probe Body Material |
316SST |
pH Electrode Junction |
Double porous |
Temperature Measurement Range |
0 to 80 °C (32 to 176 °F) |
TIENet™ Model 306 Sampler Interface |
Function |
Flow pacing, enabling based on triggered event. Time and bottle information sent to Signature Flow Meter |
Powered By |
Signature Flow Meter |
Operating Temperature |
-20 to 50°C (-4 to 122°F) |
Storage Temperature |
-40 to 60°C (-40 to 140°F) |
Pulse Width |
50 ms |
Pulse Output |
5 volts |
Sampler Connection |
Standard: 6 pin connector for Isco 6712, Avalanche, Glacier, GLS, and 3700 samplers
For other options, contact factory |
TIENet™ Model 308 Analog Output |
Output |
4-20 mA |
Isolation |
Monolithic |
Maximum Load |
500 ohm |
Outputs per card |
Two |
TIENet™ Model 310 Ultrasonic Level Sensor |
Level Measurement Range |
0.3 to 3.3m (1 to 11 ft) |
Measurement Accuracy at
72°F (22°C) |
±0.006m (0.02 ft) at 1 ft level change or less
±0.009m (0.03 ft) at greater than 1 ft level change |
Temperature Coefficient
(w/ in compensated range) |
±0.0002 x Distance (m) x Temperature Deviation from 22 °C.
±0.00011 x Distance (ft) x Temperature Deviation from 72 °F. |
Beam Angle |
10° |
Frequency |
50 kHz |
Size |
9.1 cm Ø X 10.2 cm tall (3.63" x 4") |
Cable Length |
10 or 23m (32.8 or 75.5 ft) |
Weight |
1.8 kg (4 lbs) |
Body Material |
PVDF |
Temperature Range
(Operating & Storage) |
-30° to 60°C (-22° to 140°F) |
Certifications |
Group 2, Category 1G (zone 0), T4
Class I, Div 1, Groups C & D, T4 (pending) |
TIENet™ 330 Bubbler Module |
Level Measurement Range |
0.003 to 3.05m (0.01 to 10 ft) |
Level Measurement Accuracy |
+0.002m @ 22°C (0.007 ft @ 72°F) |
Operating and storage
temperature |
-18° to 60°C (0 to 140°F) |
Temperature
Compensation Range |
0° to 60°C (32° to 140°F) |
Temperature Coefficient
(w/ in compensated range) |
±0.0003 x Level (m) x Temperature Deviation from 22 °C.
±0.00017 x Level (ft) x Temperature Deviation from 72 °F. |