The new Isco Signature flow meter is designed for open channel flow monitoring applications. It supports flow measurement technologies including ultrasonic and bubbler. Flow can be calculated using standard open channel level-to-flow conversions, level to flow data points as well as user-defined equations, depending on the needs of the application.
Unique features provided by the Signature flow meter help to verify data integrity. It logs key events such as power outages and changes in calibration to validate data accuracy. Stored data can be easily reviewed to detect any type of data alteration.
MCERTS
The Isco Model 310 Ultrasonic Level Sensor, 330 Bubbler Module, 350 Velocity Sensor and 360 LaserFlow™ Velocity Sensor are now MCERTS certified meeting the Environment Agency's performance requirements. View downloads for certificate.
The Signature® Flow Meter uses the TIENet 310 Ex Device to provide non-contact liquid level measurement. The flow meter has built-in level-to-flow conversions that cover the majority of open channel flow measurement situations. The ultrasonic sensor is mounted over the flow stream. The flow meter measures the time interval between transmission of a sound pulse from the sensor, and receiving its echo off the surface of the liquid, to determine the level of the stream.
The Signature® Flowmeter is designed for open channel flow monitoring applications using any combination of flow and parameter measurement technologies and sampling, depending on what is required at the measurement site. The bubbler level sensor can be used in almost any open channel flow application and performance is unaffected by steam or foam on the surface of the water. The bubble line is anchored in the flow stream at the appropriate measuring point in the weir, flume, or other open channel flow situation. The pressure in the bubble line is proportional to the liquid level in the flow stream sensing the liquid level.
The Teledyne Isco TIENet 350 Area Velocity Sensor measures flow stream average area velocity and liquid level. The Signature® Flow Meter uses this information to calculate the flow rate and total flow of the stream. To operate with the 350 sensor, the Signature requires software version 1.18 or later. The 350 sensor is mounted in the flow stream, normally at the bottom of the channel. It measures average velocity using continuous ultrasonic sound waves to produce a Doppler effect, in which the frequency of a wave (such as sound) passed between two bodies is relative to the motion of each. As they move nearer to each other, the frequency increases; as they move apart, the frequency decreases. The 350 sensor measures liquid level using an internal differential pressure transducer.
TIENet 360 LaserFlow Non-contacting Area Velocity Sensoriew the LaserFlow HERE
Manufactured by: Teledyne ISCO
Model: Signature Flow Meter
Industrial Pretreatment Compliance
Permit Enforcement
Wastewater Treatment Plants
Outfall
Size (HxWxD) | 8.88 x 12.22 x 8.22 in. (with mounting bracket) |
Materials of Construction | PPO Polyphenylene Oxide |
Enclosure (self-certified) | NEMA 4X/IP66 |
Power Required | 100 to 240 VAC 50/60 Hz |
Cable Entry | Standard: 3/4" NPT conduit Optional: 3/4" NPT cord grips |
Flow Measurement Technologies | Ultrasonic (TIENet 310) Bubbler (TIENet 330) |
Inputs | Two SDI-12 Two MODBUS ASCII/RTU pH Measurement (TIENet 301) |
Setup | Front Panel Keypad Flowlink Software - with serial USB, remote cellular, or Ethernet |
Flow Conversions | Weir, Flume, British Flume, Metering Insert, Manning Formula, Equation, Level to Flow Data Points |
Data Storage | Non-volatile flash; retains stored data during program updates. Capacity: 512 KB Interval: 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours Capacity: 180 days with 5 parameters logged at 1 minute intervals, reports once per day |
Data Retrieval | USB drive Flowlink Software - with serial USB, remote cellular, or Ethernet |
Outputs | MODBUS ASCII/RTU Analog (TIENet 308) SMS Alarm |
Sampler Interface | TIENet 306 |
Communication Options | CDMA or GSM cellular, Ethernet |
Temperature Range: Operating and Storage | -20 to 60°C (-4 to 140°F) |
TIENet™ 301 pH/Temperature Device | |
Weight (w/o probe) | w/ 10m cable: 3.5 lb w/ 23m cable: 7.5 lb |
Ambient Operating Temperature | -20 to 50°C (-4 to 122°F) |
pH Measurement Range | 0 - 14 pH units |
Temperature Compensation | Performed by the 301 device |
pH Accuracy | ±0.1 pH units (new probe, freshly calibrated w/in range) |
Probe Dimensions | 1.12" Ø X 6" long, 3/4 NPT; Cable 25ft |
Probe Body Material | 316SST |
pH Electrode Junction | Double porous |
Temperature Measurement Range | 0 to 80 °C (32 to 176 °F) |
TIENet™ Model 306 Sampler Interface | |
Function | Flow pacing, enabling based on triggered event. Time and bottle information sent to Signature Flow Meter |
Powered By | Signature Flow Meter |
Operating Temperature | -20 to 50°C (-4 to 122°F) |
Storage Temperature | -40 to 60°C (-40 to 140°F) |
Pulse Width | 50 ms |
Pulse Output | 5 volts |
Sampler Connection | Standard: 6 pin connector for Isco 6712, Avalanche, Glacier, GLS, and 3700 samplers For other options, contact factory |
TIENet™ Model 308 Analog Output | |
Output | 4-20 mA |
Isolation | Monolithic |
Maximum Load | 500 ohm |
Outputs per card | Two |
TIENet™ Model 310 Ultrasonic Level Sensor | |
Level Measurement Range | 0.3 to 3.3m (1 to 11 ft) |
Measurement Accuracy at 72°F (22°C) |
±0.006m (0.02 ft) at 1 ft level change or less ±0.009m (0.03 ft) at greater than 1 ft level change |
Temperature Coefficient (w/ in compensated range) |
±0.0002 x Distance (m) x Temperature Deviation from 22 °C. ±0.00011 x Distance (ft) x Temperature Deviation from 72 °F. |
Beam Angle | 10° |
Frequency | 50 kHz |
Size | 9.1 cm Ø X 10.2 cm tall (3.63" x 4") |
Cable Length | 10 or 23m (32.8 or 75.5 ft) |
Weight | 1.8 kg (4 lbs) |
Body Material | PVDF |
Temperature Range (Operating & Storage) |
-30° to 60°C (-22° to 140°F) |
Certifications | Group 2, Category 1G (zone 0), T4 Class I, Div 1, Groups C & D, T4 (pending) |
TIENet™ 330 Bubbler Module | |
Level Measurement Range | 0.003 to 3.05m (0.01 to 10 ft) |
Level Measurement Accuracy | +0.002m @ 22°C (0.007 ft @ 72°F) |
Operating and storage temperature |
-18° to 60°C (0 to 140°F) |
Temperature Compensation Range |
0° to 60°C (32° to 140°F) |
Temperature Coefficient (w/ in compensated range) |
±0.0003 x Level (m) x Temperature Deviation from 22 °C. ±0.00017 x Level (ft) x Temperature Deviation from 72 °F. |