The Heron barLog can be used alongside a non-vented (absolute) dipperLog to provide barometric compensation.
A barometric logger is used to automatically compensate readings stored on the dipperLog data logger for changes in barometric pressure (for non-vented version). The Heron barLog is recommended for long term monitoring or where more than one logger is deployed within a 5km/3mi radius.
The easy-to-use dipperLog software allows user set reading intervals. The inbuilt memory has storage capacity for 128,000 data points.
Manufactured by: Heron Instruments
Model: barLog Barometric Logger
| Performance | |
| # of Data Points | 128,000 |
| Download Speed | 21,333.33/min |
| Water Level Accuracy (Typical) | +/- 0.05% FS (0°C to 50°C) |
| Temperature Accuracy (Typical) | +/- 0.05°C Temperature Sensor Meets ASTM El 112 and ISO 80601-2-56. NIST Traceabili1y. |
| Operating Features | |
| Pressure Ranges | N/A |
| Overpressure Rating | 2X Factory Calibrated Range |
| Operating Temperature | -20°C to 80°C (-5° F to 175°F) |
| Pressure Resolution % FS | 0.01 |
| Expected Battery Life* | Up to 5,000,000 Readings Up to 15 Years |
| Warranty | 2 Years |
| Physical Characteristics | |
| Wetted Material | N/A |
| O-Ring (Primary) | Buna-N |
| O-Ring (Backup) | Viton |
| Transducer | 316 SS Piezoresistive Silicon |
| Length | 145mm / 5. 7" |
| Diameter | 22mm / 0.87" |
| Weight | 170g |
* depending on use